Grundfos CRN2/4 pump mechanical seal replacement
- Replacement of grundfos CRN2/4 pump mechanical seal replacement, non-cartridge type ,Single spring design, unbalanced seal, used in water pump
Replacement seal for Grundfos CRN2/4 pumps
This page covers the pictured non-cartridge, single-spring replacement mechanical seal offered for CRN2/4 pump repair enquiries. A pump model alone is not enough to confirm interchangeability: compare the removed seal, pump nameplate and installation dimensions before ordering. This is an aftermarket replacement enquiry, not a claim that the part is a genuine Grundfos service kit.
Published operating limits and material options
- Temperature: -10 to 120°C
- Sliding speed: up to 10 m/s
- Pressure: up to 12 bar
- Published size range: 25–100 mm; the size required for an individual CRN2/4 installation must be confirmed.
These are the existing catalogue limits for the offered seal range, not a verified duty rating for every CRN2/4 pump. Temperature, pressure and speed must be reviewed together with the selected materials and the actual liquid.
- Seal face options: carbon, silicon carbide, sintered silicon carbide and tungsten carbide.
- Secondary seal options: NBR, EPDM and FKM (Viton), subject to liquid and cleaning-fluid compatibility.
- Spring and metal-part options: 304, 316 and Hastelloy C, subject to confirmation for the supplied configuration.
Build a CRN2/4 old-seal comparison record
Keep the rotating assembly and stationary seat together when recording the removed part. Photograph both sides before cleaning away deposits, then add a separate set of clean measurement photographs. This helps distinguish the original geometry from wear, scale or a damaged rubber profile.
- Identify the pump: provide the complete nameplate, product number and any readable shaft-seal or service-kit marking. Record previous seal changes if known.
- Record the rotating part: measure the shaft or sleeve at the seal location, the rotating assembly outside diameter and its axial envelope. Include the drive feature and spring arrangement in the photographs.
- Record the seat: measure the stationary seat outside diameter, seat thickness and the housing bore. Show whether the seat uses an O-ring or a rubber cup, and photograph any locating feature.
- Separate free height from working length: label loose-part measurements as free height. Do not treat a worn seal’s loose height as the installed working length; use the pump service information or an approved assembly drawing for that dimension.
When the shaft size matches but the seat does not
For example, an enquiry may include a matching shaft diameter but a different stationary seat thickness. Keep that enquiry open until the seat and installed axial position have been compared. A shared shaft size does not establish the spring compression or the fit in the seat pocket. This is a checking example, not a confirmed CRN2/4 fitment or customer case.
What to include in a replacement enquiry
Send the nameplate, old-seal photographs, a dimension sketch and required quantity. Add the pumped liquid, normal and maximum temperature, operating pressure, speed, cleaning chemicals and a brief description of the leakage. If a dimension is unavailable, mark it as unknown rather than estimating it.
Before releasing a repeat order, retain the agreed drawing or sample reference alongside the pump identity and material combination. This gives maintenance and purchasing teams a common reference when two similar-looking seals are stored together.
CRN2/4 replacement questions
Can I order from the product photograph alone?
A photograph helps identify the arrangement, but it cannot establish seat fit or working length. Supply dimensions and the complete pump identification for comparison.
Does the 25–100 mm range confirm my pump’s seal size?
No. It is the published range on this supplier page. The particular seal size and configuration must be checked against the pump and removed assembly.
What if the pump leaks again after fitting a new seal?
Record when leakage begins and inspect the mating installation surfaces, shaft or sleeve, seat pocket and operating conditions using the pump service procedure. Repeated leakage is a reason to investigate the assembly and duty, not to select another part solely by appearance.
Browse the Grundfos replacement seal range, review mechanical seal material options, or send a CRN2/4 seal enquiry with your comparison record.
Some others you may like
Four checks before ordering
Pump identity
Keep the complete nameplate and product number with the seal enquiry so similar CRN2/4 pump labels are not treated as a complete fitment reference.
Seat geometry
Compare stationary seat diameter, thickness, rubber profile and housing fit. Matching the shaft diameter alone leaves these important dimensions unresolved.
Operating duty
Record the liquid, temperature, pressure, speed and cleaning chemicals together. Confirm the face and elastomer combination for that duty before ordering.
Repeat-order reference
Store the agreed drawing or sample reference with the pump identity and material specification. Use that record when ordering the next replacement.